Company Information

Optimal Home Inspections LLC

Phone: (551) 261-1264
marshdak@gmail.com
https://optimalhomeinspections.com/

Inspected by: Marshal Datkowitz
NJ State Home Inspector #: 24GI00176700

Overall, this appears to have been a moderately well-built 1990's home that has had some updates over time. This house was reasonably maintained but can use caulking around the exterior windows and bathrooms ceramic tile. The roof has at least two layers of shingles with a few lifting shingles, flashing appears functional. Major concerns include cut trusses in the attic above the garage ceiling access and possible water intrusion in the master bath shower. Active water leaks were observed under the kitchen sink and under the water pressure regulator in the garage utility area. All major concerns and repairs in the report should be addressed before closing of the real estate transaction.

The Scope and Purpose of a Home Inspection

Purchasing property involves risk

The purpose of a home inspection is to help reduce the risk associated with the purchase of a structure by providing a professional opinion about the overall condition of the structure. A home inspection is a limited visual inspection and it cannot eliminate this risk. Some homes present more risks than others. We cannot control this, but we try to help educate you about what we don’t know during the inspection process. This is more difficult to convey in a report and one of many reasons why we recommend that you attend the inspection.

A home inspection is not an insurance policy

This report does not substitute for or serve as a warranty or guarantee of any kind. Home warranties can be purchased separately from insuring firms that provide this service.

A home inspection is visual and not destructive

The descriptions and observations in this report are based on a visual inspection of the structure. We inspect the aspects of the structure that can be viewed without dismantling, damaging or disfiguring the structure and without moving furniture and interior furnishings. Areas that are concealed, hidden or inaccessible to view are not covered by this inspection. Some systems cannot be tested during this inspection as testing risks damaging the building. For example, overflow drains on bathtubs are generally not tested because if they were found to be leaking they could damage the finishes below. Our procedures involve non-invasive investigation and non-destructive testing which will limit the scope of the inspection.

This is not an inspection for code compliance

This inspection and report are not intended for city / local code compliance. During the construction process structures are inspected for code compliance by municipal inspectors. Framing is open at this time and conditions can be fully viewed. Framing is not open during inspections of finished homes, and this limits the inspection. All houses fall out of code compliance shortly after they are built, as the codes continually change. National codes are augmented at least every three years for all of the varying disciplines. Municipalities can choose to adopt and phase in sections of the codes on their own timetables. There are generally no requirements to bring older homes into compliance unless substantial renovation is being done.

This is just our opinion

Construction techniques and standards vary. There is no one way to build a house or install a system in a house. The observations in this report are the opinions of the home inspector. Other inspectors and contractors are likely to have some differing opinions. You are welcome to seek opinions from other professionals.

The scope of this inspection

This inspection will include the following systems: exterior, roof, structure, drainage, foundation, attic, interior, plumbing, electrical and heating. The evaluation will be based on limited observations that are primarily visual and non-invasive. This inspection and report are not intended to be technically exhaustive.

Your expectations

The overall goal of a home inspection is to help ensure that your expectations are appropriate with the house you are proposing to buy. To this end we assist with discovery by showing and documenting observations during the home inspection. This should not be mistaken for a technically exhaustive inspection designed to uncover every defect with a building. Such inspections are available but they are generally cost-prohibitive to most homebuyers.

Your participation is requested

Your presence is requested during this inspection. A written report will not substitute for all the possible information that can be conveyed verbally by a shared visual observation of the conditions of the property.

How to Read This Report

Getting the Information to You

This report is designed to deliver important and technical information in a way that is easy for anyone to access and understand. If you are in a hurry, you can take a quick look at our "Summary Page” and quickly get critical information for important decision making. However, we strongly recommend that you take the time to read the full Report, which includes digital photographs, captions, diagrams, videos and hot links to additional information.

The best way to get the layers of information that are presented in this report is to read your report online. This will allow all you to expand your learning about your house. You will notice some words or series of words highlighted in blue and underlined – clicking on these will provide you with a link to additional information.

This report can also be printed on paper or to a PDF document.

Chapters and Sections

This report is divided into chapters that parcel the home into logical inspection components. Each chapter is broken into sections that relate to a specific system or component of the home. You can navigate between chapters with the click of a button on the left side margin.

Most sections will contain some descriptive information done in black font. Observation narrative, done in colored boxes, will be included if a system or component is found to be significantly deficient in some way or if we wish to provide helpful additional information about the system or the scope of our inspection. If a system or component of the home was deemed to be in satisfactory or serviceable condition, there may be no narrative observation comments in that section.

Observation Labels

All narrative observations are colored, numbered and labeled to help you find, refer to, and understand the severity of the observation. Observation colors and labels used in this report are:

  • Major Concern:
    Repair items that may cost significant money to correct now or in the near future, or items that require immediate attention to prevent additional damage or eliminate safety hazards.
  • Repair:
    Repair and maintenance items noted during inspection. Please note that some repair items can be expensive to correct such as re-finishing hardwood floors, but are considered simply repair items due to their cosmetic nature.
  • Improve:
    Observations that are not necessarily defects, but which could be improved for safety, efficiency, or reliability reasons.
  • Monitor:
    Items that should be watched to see if correction may be needed in the future.
  • Due Diligence:
    Observation such as a buried oil tank that may require further investigation to determine the severity and / or urgency of repair.
  • Future Project:
    A repair that may be deferred for some time but should be on the radar for repair or replacement in the near future.
  • Efficiency:
    Denotes observations that are needed to make the home more energy efficient as well as to bring the home up to modern insulation standards. This category typically includes windows and insulation. Other items, such as lighting and appliances, are not inspected for their energy status.
  • Completed:
    Items that were initially an issue but have since been completed.
  • Note:
    Refers to aside information and /or any comments elaborating on descriptions of systems in the home or limitations to the home inspection.

Summary Page

The Summary Page is designed as a bulleted overview of all the observations noted during inspection. This helpful overview is not a substitution for reading the entire inspection report. The entire report must be read to get a complete understanding of this inspection report as the Summary Page does not include photographs or photo captions.

Summary

Major Concerns

  • (RA-6) Roof/Attic:

    Physical damage was noted to the roof trusses (above garage pull down stairs) that could weaken this engineered roof structure. On site modifications to engineered trusses are not allowed and trusses must not be damaged during installation. If trusses are modified or damaged on site in any way, they require further evaluation by a structural engineer or a registered design professional to engineer a proper repair. Hire an engineer or registered truss design professional before closing to further evaluate this truss installation and make repairs as recommended to insure the trusses are installed as intended and retain paper work of repairs for your records.

  • (MB-5) Master Bathroom:

    Loose tile were noted in the shower surround, hollow sound behind the tile was heard as well as localized failing grout and caulking. This indicates water is getting behind the tile and causing damage. Temporary repairs can be made with caulking and grout sealer - more long term repairs may necessitate tile replacement depending on what the tile is mounted on and what adhesives were used to mount the tile. We recommend additional inspection by a qualified tile setter to determine an accurate scope and urgency of repair. This further evaluation could conclude a simple repair or the need for a larger project such as full tile replacement, a significant expense.

Repairs

  • (G-1) Grounds:

    Downspouts are discharging adjacent to the foundation and walkway. This can cause foundation settlement or basement / crawl space moisture problems. Make sure all downspouts discharge into a proper system that diverts water at least 5 feet away from the foundation.

  • (G-3) Grounds:

    Where the foundation meets concrete surfaces should be caulked; moisture can enter the foundation; we recommend a qualified contractor evaluate all foundation/concrete joints and repair as necessary.

  • (G-4) Grounds:

    At front of building beside garage, concrete is deteriorating; to reduce further deterioration we recommend a qualified mason or general contractor repair as required.

  • (G-5) Grounds:

    All trees, branches and vegetation should be pruned at least six feet away from the building to eliminate a condition conducive to wood destroying organisms and a path for rodent entry.

  • (E1-2) Exterior:

    Trim was observed in several areas to be loose; nails backing out; we recommend a qualified contractor or handyman secure all loose trim.

  • (E1-3) Exterior:

    Several areas of soffit vent screen were noted to be loose, missing and in need of repair to prevent bird and rodent entry. We recommend a qualified contractor evaluate all eaves and repair as needed.

  • (E1-6) Exterior:

    The exterior deck stairs are missing a graspable handrail for safety. This should be a round railing 1 and 1/4 inches - 2 inches in diameter. If the railing is not round it must have a finger groove that is 3/4 of an inch down from the tallest point of the rail. The graspable handrail should also be 1.5 inches from the wall. 2x material is not considered a graspable handrail. We recommend a qualified contractor build suitable railings to reduce the potential for falls.

    Guards are open and climbable by a child; this is a safety hazard; we recommend a qualified contractor evaluate and repair as needed.

  • (E1-7) Exterior:

    (Wooden deck) Support posts - do not appear to be set on concrete, the posts are wood to ground contact which rots wood and attracts termites, we recommend a qualified contractor evaluate the entire deck before closing and repair as needed.

  • (E1-10) Exterior:

    Windows: General maintenance required, caulk, seal, maintain and repair when necessary, window damage noted in one or more windows there is moisture between the layers of glass, A qualified glazier is recommended to evaluate all windows and estimate repairs before closing.

  • (GC(1)-1) Garage/Carport:

    The garage door did not reverse when it met with resistance. The resistance for the Garage door opener(s) was dangerous at the time of this inspection. The resistance should be adjusted so the opener will reverse with less resistance. An opener with poor resistance can cause an injury to a child and or a pet until properly adjusted. This is a safety issue that needs to be corrected. This adjustment is usually as simple as turning a screw on the overhead opener. You may need to contact the manufacture for further information and/or go online to the manufactures website to obtain the owners manual. We recommend adjusting the resistance so the door will reverse properly when met with resistance. Have a qualified contractor evaluate the garage door before closing and repair as required.

  • (GC(1)-2) Garage/Carport:

    Several openings in the drywall ceiling and walls were observed. We recommend a qualified contractor evaluate the walls and ceiling and repair as required.

  • (RA-2) Roof/Attic:

    The roofing material on this building appears to be dimensional or architectural grade shingle. These are often rated as 30-year shingles. In practice, as a roof assembly, we find these last closer to 18-22 years depending on the quality of the installation, the steepness of the roof and the amount of exposure. The installation appears neat and professional but a few repairs are needed. Hire a licensed roofing contractor to further evaluate and repair the roof to ensure reliable performance. Examples of specific observations noted during inspection include:

  • (RA-3) Roof/Attic:

    Vents/plumbing: (standard pipe vents) General periodic vent pipe flashing maintenance is recommended to avoid roof leaks, One has to go on roof to check or service flashings which is outside the scope of a home inspection

  • (RA-5) Roof/Attic:

    Improvised unfastened flooring in attic is placed over wiring, this is a fire hazard, recommend the removal of all unsecured flooring that has been placed over wiring. Recommend consulting with a qualified contractor to assess the appropriateness of having any storage in the attic.

  • (RA-7) Roof/Attic:

    Items have been stored on the bottom cord of a truss system. Truss systems need to be engineered for storage. Many trusses are not intended for live storage loads and in extreme cases storage can cause the trusses to buckle and fail. Remove storage items from the garage area.

  • (E1-11) Roof/Attic:

    No carry-off observed; green growth noted indicating water may be pooling here. We recommend a a carry-off be added here to direct water away from the foundation. In the winter water may freeze here creating a trip hazard.

  • (I-2) Interior:

    The door to the bedroom closet is not latching and requires adjustment so the door latches closed.

  • (I-3) Interior:

    A lost seal was noted in the glazing (dining room). This has resulted in fogging between the panes of glass that cannot be cleaned without glazing repair or replacement. Hire a glazing specialist to further evaluate and repair or replace all glazing with lost seals.

  • (I-4) Interior:

    The bath fans appear to be venting into the attic. This is non-standard and could contribute to condensation and mold problems in the attic. Repair all fans to be ducting to the exterior of the home. Best practices are to vent through the roof and insulate the ducts.

  • (K-1) Kitchen:

    The p-trap below the kitchen sink is leaking; recommend a licensed plumber repair before closing.

  • (K-3) Kitchen:

    The range in the kitchen is loose and not adequately mounted to the floor. This is a safety hazard as hot items on the cooktop could fall off. Have a proper anti-tip device installed to insure safe and reliable performance.

  • (MB-2) Master Bathroom:

    Slow drain at master bathroom sink with gurgling which may indicate that the drain line needs to be cleaned and/or that the drain is not properly vented. Recommend a licensed plumber evaluate and repair as needed.

  • (MB-4) Master Bathroom:

    The tile and grout should be cleaned and sealed with grout sealer to prevent water damage to the tile - see especially inside shower surrounds. This should be a routine procedure with tile unless epoxy grout was used. If this is not done in epoxy grout plan on annual cleaning and sealing tile grout inside the shower surrounds to prolong the useful life of the tile.

  • (MB-6) Master Bathroom:

    The fan in the bath did not appear operational. We tried all switches on the walls and the fan did not come on. Have this fan evaluated by a licensed electrician or qualified contractor and repaired as needed to insure adequate ventilation for this bathroom.

  • (B1-3) Bathroom:

    Fan vent ducting appears to be terminated in the attic; moisture can build up in the attic and damage the structure. We recommend a qualified contractor evaluate all the bathroom ducting in the house and repair as needed.

  • (E-3) Electrical:

    Contamination (paint splatter, drywall compound and other items) and excessive insulation on wires in panel; this is a fire hazard. Recommend a licensed electrician correct.

  • (E-4) Electrical:

    A piece of wood is filling the space between the dead front panel door and the wall; this is a fire hazard. Recommend a licensed electrician or qualified general contractor correct.

  • (E-5) Electrical:

    Inquire with the seller about the extension cord used. What is this for? Extension cords should not be used for permanent electrical fixtures. Install proper wiring or remove extension cord as needed.

  • (P-2) Plumbing:

    The pressure reducing valve located in the garage across from the water heater is corroded and appears to be actively leaking at the time of inspection. We recommend further investigation and repair by a licensed plumber.

  • (P-3) Plumbing:

    The floor below the pressure reducing valve is water soaked and structurally damaged, we recommend a qualified contractor, evaluate before closing, all the flooring and structure below it and repair as needed.

  • (P-4) Plumbing:

    The supply pipe insulation is incomplete in the crawl space. Be sure all supply lines in unheated spaces have been adequately insulated to protect from freezing conditions that could damage the pipes and to prevent heat loss. We recommend a qualified contractor evaluate and correct.

  • (P-6) Plumbing:

    The discharge tube for the water heater relief valve is installed too high off the ground. Discharge tubes should always terminate by pointing toward the ground to eliminate a scald hazard and should be no more than 6" off the ground. Ideally, the discharge tube terminates to an exterior or unfinished location or above a drain, though this is not always possible. The drain should also slope to drain to prevent water pooling inside the discharge tube and should be visible so it can be monitored. The end of the tube should not be threaded to prevent accidental capping of this important discharge. Have a licensed plumber evaluate and repair before the closing.

  • (H1-2) Heating:

    Annual servicing is recommended for safe and reliable heat. Records indicate that this boiler has not been serviced in the last year. The boiler was tested during inspection and was operational. Hire a licensed heating contractor to service and further evaluate the boiler.

  • (H1-3) Heating:

    Corrosion observed at boiler vent and surrounding valves; this can leak or burst; we recommend a licensed HVAC contractor evaluate the boiler before closing and repair as required.

  • (C-3) Cooling:

    AC Condenser power switch is rusted and loosely attached to the siding; this is a fire hazard; we recommend a licensed electrician evaluate the service box before closing and repair/replace as required.

  • (CS-1) Crawl Space:

    The plastic vapor barrier in the crawl space is incomplete. Use 6 mil black plastic to cover all exposed earth. This helps to reduce humidity and eliminate conducive pest conditions in the crawl space.

  • (CS-2) Crawl Space:

    Moisture observed from crawl space; this may be under the water pressure reducing valve in garage utility area; we recommend a qualified contractor evaluate all the floor sheathing and structure in the crawl space before closing.

Improves

  • (G-6) Grounds:

    To eliminate a condition conducive to wood destroying organisms, remove the wood perimeter material (wood mulch) where used for landscaping as this wood could be conducive to carpenter ants and other wood destroying organisms.

  • (P-8) Plumbing:

    For improved reliability, update the old water supply connectors to the washing machine. These are old and should be regularly swapped out to prevent accidental leaks from bursting hoses. Consider improving the reliability of this water supply by installing a steel belted hose system.

  • (P-9) Plumbing:

    A moisture alarm with water shut-off features is recommended under the washing machine to protect against accidental leaks in the supply hoses. Pans can be effective when there is a drain, but even these will not protect against a burst supply connector. A moisture alarm with automatic shut-off will.

Due Diligences

  • (FSD-1) Fuel Storage and Distribution:

    Gas meter was not observed; it's possible located behind the sellers stored materials; we recommend you ask the seller to point out the meter before closing; we recommend the meter be inspected before closing.

Notes

  • (G-2) Grounds:

    Regrade where needed

  • (E1-8) Exterior:

    Seller stated that the deck was added on to an existing deck; it appears that a screened in porch was added on top of the existing deck; we recommend a qualified contractor evaluate the construction of the screened porch, existing deck and added on deck before closing and repair as needed.

  • (E1-9) Exterior:

    The structure of the deck is inaccessible and was not inspected. We recommend a qualified general contractor further evaluate.

  • (RA-4) Roof/Attic:

    Estimated shingle layers: appears as two layers - the layers of shingle is estimated from a side view of the shingles at the edge of the roof, However, many times the shingle edge is covered with metal and not exposed. The inspector is not allowed to lift shingles to determine the exact number of shingle layers. MAINTENANCE NOTE - if there are two layers of shingle, more than normal maintenance is required on the roof and flashings due to the age of the old flashings.

  • (RA-8) Roof/Attic:

    Temperature controlled cooling fan observed in attic; due to lower temperatures could not be tested.

  • (MB-1) Master Bathroom:

    Regrout all floor and/or wall tile as needed to prevent leakage and drainage.

  • (B1-1) Bathroom:

    Regrout all floor and/or wall tile as needed to prevent leakage and drainage.

  • (B1-2) Bathroom:

    The jetted tub was filled and tested during inspection today.

  • (P-5) Plumbing:

    Water heaters have an expected useful life of 6 to 12 years; this water heater is 18 years old.

  • (P-10) Plumbing:

    It is recommended that the exhaust pipe and flex pipe be cleaned and changed shortly after you have closed on this home to guarantee that the dryer exhaust system is safe and working efficiently.

  • (C-4) Cooling:

    The air condition system and condensate control system could not be tested during inspection. Outdoor temperatures must exceed 65 degrees or the air conditioning equipment can be damaged by testing. We recommended having this system serviced and inspected prior to the next cooling season.

General Comments

Building Characteristics / Conditions

Style of Home Contemporary

Type of Building Residential Single Family (1 story)

Approximate Square Footage 1550

Approximate Year of Original Construction 1990, 29 years

Attending the Inspection Seller, Buyer and Buyer's Agent

Occupancy Occupied- occupants in the process of moving

Animals Present No

Weather during the inspection Clear

Approximate temperature during the inspection Below 65[F]

Ground/Soil surface conditions Wet

House Layout

Levels

Lowest Level Crawl Space

First Floor 2 Bathrooms, 2 Bedrooms, Living Room/Dining Room Combination, Kitchen w/breakfast, Laundry Closet

Grounds

Drainage and Lot Location

Clearance to Grade Standard

Downspout Discharge Above and below grade

Lot Description Moderate slope

(G-1) Repair:

Downspouts are discharging adjacent to the foundation and walkway. This can cause foundation settlement or basement / crawl space moisture problems. Make sure all downspouts discharge into a proper system that diverts water at least 5 feet away from the foundation.

(G-2) Note:

Regrade where needed

(G-3) Repair:

Where the foundation meets concrete surfaces should be caulked; moisture can enter the foundation; we recommend a qualified contractor evaluate all foundation/concrete joints and repair as necessary.

Driveways/Walkways/Flatwork

Driveway Asphalt

Walkways Concrete

Patios None noted

(G-4) Repair:

At front of building beside garage, concrete is deteriorating; to reduce further deterioration we recommend a qualified mason or general contractor repair as required.

Grounds, Trees and Vegetation

Trees/Vegetation too near building Yes

(G-5) Repair:

All trees, branches and vegetation should be pruned at least six feet away from the building to eliminate a condition conducive to wood destroying organisms and a path for rodent entry.

(G-6) Improve:

To eliminate a condition conducive to wood destroying organisms, remove the wood perimeter material (wood mulch) where used for landscaping as this wood could be conducive to carpenter ants and other wood destroying organisms.

Retaining Walls

None noted

Fences

None noted

Outbuildings and Other

None noted

Exterior

NJ Standard of Practice

Siding and Trim

Siding Material - All; Front; Sides; Rear Vinyl

Trim Material - All; Fascia; Soffit; Other Metal, Vinyl

Condition Functional

(E1-2) Repair:

Trim was observed in several areas to be loose; nails backing out; we recommend a qualified contractor or handyman secure all loose trim.

Eaves

Vinyl, Metal

Condition Marginal

(E1-3) Repair:

Several areas of soffit vent screen were noted to be loose, missing and in need of repair to prevent bird and rodent entry. We recommend a qualified contractor evaluate all eaves and repair as needed.

Porches / Stoops

Standard

Porches / Stoops Front, Concrete

Condition Functional

Decks and Balconies

Present

Deck Structure Ground contact lumber

Deck Ledger Board Not visible

Guardrail Non-standard

Decking Material Painted wood

Condition Marginal

(E1-6) Repair:

The exterior deck stairs are missing a graspable handrail for safety. This should be a round railing 1 and 1/4 inches - 2 inches in diameter. If the railing is not round it must have a finger groove that is 3/4 of an inch down from the tallest point of the rail. The graspable handrail should also be 1.5 inches from the wall. 2x material is not considered a graspable handrail. We recommend a qualified contractor build suitable railings to reduce the potential for falls.

Guards are open and climbable by a child; this is a safety hazard; we recommend a qualified contractor evaluate and repair as needed.

(E1-7) Repair:

(Wooden deck) Support posts - do not appear to be set on concrete, the posts are wood to ground contact which rots wood and attracts termites, we recommend a qualified contractor evaluate the entire deck before closing and repair as needed.

(E1-8) Note:

Seller stated that the deck was added on to an existing deck; it appears that a screened in porch was added on top of the existing deck; we recommend a qualified contractor evaluate the construction of the screened porch, existing deck and added on deck before closing and repair as needed.

(E1-9) Note:

The structure of the deck is inaccessible and was not inspected. We recommend a qualified general contractor further evaluate.

Driveways/Walkways/Flatwork

Driveway Asphalt

Walkways Concrete

Condition Functional

Window and Stairwells

Present

(E1-10) Repair:

Windows: General maintenance required, caulk, seal, maintain and repair when necessary, window damage noted in one or more windows there is moisture between the layers of glass, A qualified glazier is recommended to evaluate all windows and estimate repairs before closing.

Exterior Doors

Material Solid core, Sliding glass, Metal

Condition Functional

Exterior Window Frames

Material Metal, Vinyl

Condition Functional

Garage/Carport

Description

Type Attached

Special Comments Limited View Storage

Roof Materials

For Attached Garages see Exterior Roofing See Exterior section

Exterior Windows

Type Vinyl

Condition Not Completely Visible, Limited access due to Seller's storage

Vehicle Doors

1

Automatic Garage Opener Present

Garage Door Type Metal

Condition Marginal

(GC(1)-1) Repair:

The garage door did not reverse when it met with resistance. The resistance for the Garage door opener(s) was dangerous at the time of this inspection. The resistance should be adjusted so the opener will reverse with less resistance. An opener with poor resistance can cause an injury to a child and or a pet until properly adjusted. This is a safety issue that needs to be corrected. This adjustment is usually as simple as turning a screw on the overhead opener. You may need to contact the manufacture for further information and/or go online to the manufactures website to obtain the owners manual. We recommend adjusting the resistance so the door will reverse properly when met with resistance. Have a qualified contractor evaluate the garage door before closing and repair as required.

Walls/Ceilings/Floor

Wall Material Drywall

Condition Marginal, Not Completely Visible

Ceiling Matreial Drywall

Condition Marginal

Floor Material Concrete

Condition Functional

(GC(1)-2) Repair:

Several openings in the drywall ceiling and walls were observed. We recommend a qualified contractor evaluate the walls and ceiling and repair as required.

Roof/Attic

NJ Standard of Practice

Roofing

Method of Roof Inspection Viewed with binoculars, Viewed from inside attic

Roof Style Complex Gable

Roof Materials Architectural grade composition shingle

# of Layers +2

Approximate Age of Roof Unknown, no documentation was supplied, estimated effective age of the roof is 10 years

Roof Condition Marginal

Flashing Material Metal

Flashing Condition Marginal

(RA-2) Repair:

The roofing material on this building appears to be dimensional or architectural grade shingle. These are often rated as 30-year shingles. In practice, as a roof assembly, we find these last closer to 18-22 years depending on the quality of the installation, the steepness of the roof and the amount of exposure. The installation appears neat and professional but a few repairs are needed. Hire a licensed roofing contractor to further evaluate and repair the roof to ensure reliable performance. Examples of specific observations noted during inspection include:

(RA-3) Repair:

Vents/plumbing: (standard pipe vents) General periodic vent pipe flashing maintenance is recommended to avoid roof leaks, One has to go on roof to check or service flashings which is outside the scope of a home inspection

(RA-4) Note:

Estimated shingle layers: appears as two layers - the layers of shingle is estimated from a side view of the shingles at the edge of the roof, However, many times the shingle edge is covered with metal and not exposed. The inspector is not allowed to lift shingles to determine the exact number of shingle layers. MAINTENANCE NOTE - if there are two layers of shingle, more than normal maintenance is required on the roof and flashings due to the age of the old flashings.

Attic

Walked, Partially floored

Condition Marginal

(RA-5) Repair:

Improvised unfastened flooring in attic is placed over wiring, this is a fire hazard, recommend the removal of all unsecured flooring that has been placed over wiring. Recommend consulting with a qualified contractor to assess the appropriateness of having any storage in the attic.

Roof Framing and Sheathing

Rafters Truss

Condition Marginal, See Comments and Recommendations, Not Completely Visible

Sheathing OSB

Condition Acceptable, Not Completely Visible

Joists Partially Finished Not Completely Visible, Truss

Condition Functional, Not Completely Visible

(RA-6) Major Concern:

Physical damage was noted to the roof trusses (above garage pull down stairs) that could weaken this engineered roof structure. On site modifications to engineered trusses are not allowed and trusses must not be damaged during installation. If trusses are modified or damaged on site in any way, they require further evaluation by a structural engineer or a registered design professional to engineer a proper repair. Hire an engineer or registered truss design professional before closing to further evaluate this truss installation and make repairs as recommended to insure the trusses are installed as intended and retain paper work of repairs for your records.

(RA-7) Repair:

Items have been stored on the bottom cord of a truss system. Truss systems need to be engineered for storage. Many trusses are not intended for live storage loads and in extreme cases storage can cause the trusses to buckle and fail. Remove storage items from the garage area.

Attic Insulation

Insulation Type Fiberglass

Approximate Insulation R-Value on Attic Floor 30 (in some places), Compressed by improvised flooring so true R-Value unknown

Approximate Insulation R-Value on Attic Ceiling 0

Attic and Roof Cavity Ventilation

Attic Ventilation Method Ridge vents, Soffit vents, Front porch ceiling vented to attic

Evidence of Leakage

None Observed at Time of Inspection

Chimneys

Number Present

Chimney Material Metal

Condition Functional

Gutters and Downspouts

Gutter Material Seamless Aluminum

Leaders / Carryoff Type Splash blocks, Extenders

Condition Marginal

(E1-11) Repair:

No carry-off observed; green growth noted indicating water may be pooling here. We recommend a a carry-off be added here to direct water away from the foundation. In the winter water may freeze here creating a trip hazard.

Special Features

Attic Fan

Condition Not Completed

(RA-8) Note:

Temperature controlled cooling fan observed in attic; due to lower temperatures could not be tested.

Interior

NJ Standard of Practice

Floors

Floor Materials Hardwood, Tile, Wood Laminate

Floor Settlement Minor

Condition Functional

Walls, Ceilings, Trim and Closets

Wall and Ceiling Materials Drywall

Condition Functional

Stairs and Railings

None

Interior Doors

Hollow Core

Condition Functional

(I-2) Repair:

The door to the bedroom closet is not latching and requires adjustment so the door latches closed.

Windows

Window Glazing Double pane

Interior Window Frame Vinyl

Window Styles Double hung

Condition Marginal

(I-3) Repair:

A lost seal was noted in the glazing (dining room). This has resulted in fogging between the panes of glass that cannot be cleaned without glazing repair or replacement. Hire a glazing specialist to further evaluate and repair or replace all glazing with lost seals.

Mechanical Ventilation

Bath Fan Ducting Ducted to attic

Kitchen Fan Ducting Ducted to exterior

(I-4) Repair:

The bath fans appear to be venting into the attic. This is non-standard and could contribute to condensation and mold problems in the attic. Repair all fans to be ducting to the exterior of the home. Best practices are to vent through the roof and insulate the ducts.

Kitchen

Walls, Ceilings and Floor

Wall Material Ceramic Tile, Drywall

Ceiling Material Drywall

Floor Material Hardwood

Condition Functional

Doors and Windows

Door Material None

Primary Window Material Vinyl

Condition Functional, Window over sink inaccessible and not inspected

Sinks and Faucets

Tested

Condition Functional, P-trap Marginal

(K-1) Repair:

The p-trap below the kitchen sink is leaking; recommend a licensed plumber repair before closing.

Cabinets and Countertops

Countertop Material Man made material

Cabinet Material Wood

Condition Functional

Ventilation Method

Fan ducted to unknown area

Appliances

Refrigerator Operating

Dishwasher Operated

Dishwasher Air Gap Just a high loop

Range/ Oven /Cook-tops Gas, Electric

Disposer Operated

(K-3) Repair:

The range in the kitchen is loose and not adequately mounted to the floor. This is a safety hazard as hot items on the cooktop could fall off. Have a proper anti-tip device installed to insure safe and reliable performance.

General Kitchen Condition

Standard

Master Bathroom

Walls/Ceiling/Floors

Wall Material Drywall

Condition Functional

Ceiling Material Drywall

Condition Functional

Floor Material Ceramic Tile

Condition Functional

(MB-1) Note:

Regrout all floor and/or wall tile as needed to prevent leakage and drainage.

Doors and Windows

Door Type Wood

Condition Functional

Primary Window Type Vinyl

Condition Functional

Sinks and Cabinets

Tested

Condition Marginal

(MB-2) Repair:

Slow drain at master bathroom sink with gurgling which may indicate that the drain line needs to be cleaned and/or that the drain is not properly vented. Recommend a licensed plumber evaluate and repair as needed.

Bathroom Plumbing Fixtures

Tested

Condition Functional

Bathtub / Shower

Tested

Condition Marginal, See Comments and Recommendations

(MB-4) Repair:

The tile and grout should be cleaned and sealed with grout sealer to prevent water damage to the tile - see especially inside shower surrounds. This should be a routine procedure with tile unless epoxy grout was used. If this is not done in epoxy grout plan on annual cleaning and sealing tile grout inside the shower surrounds to prolong the useful life of the tile.

(MB-5) Major Concern:

Loose tile were noted in the shower surround, hollow sound behind the tile was heard as well as localized failing grout and caulking. This indicates water is getting behind the tile and causing damage. Temporary repairs can be made with caulking and grout sealer - more long term repairs may necessitate tile replacement depending on what the tile is mounted on and what adhesives were used to mount the tile. We recommend additional inspection by a qualified tile setter to determine an accurate scope and urgency of repair. This further evaluation could conclude a simple repair or the need for a larger project such as full tile replacement, a significant expense.

Bathroom Ventilation

Type Bath fan

Termination Point Uknown

Condition See Comments and Recommendations

(MB-6) Repair:

The fan in the bath did not appear operational. We tried all switches on the walls and the fan did not come on. Have this fan evaluated by a licensed electrician or qualified contractor and repaired as needed to insure adequate ventilation for this bathroom.

Bathroom

Walls/Ceiling/Floors

Wall Material Drywall

Condition Functional

Ceiling Material Drywall

Condition Functional

Floor Material Ceramic Tile

Condition Functional

(B1-1) Note:

Regrout all floor and/or wall tile as needed to prevent leakage and drainage.

Doors and Windows

Door Type Wood

Condition Functional

Primary Window Type None

Sinks and Cabinets

Tested

Bathroom Plumbing Fixtures

Tested

Condition Functional

Bathtub / Shower

Tested

(B1-2) Note:

The jetted tub was filled and tested during inspection today.

Bathroom Ventilation

Type Bath fan

Termination Point Attic

Condition Marginal

(B1-3) Repair:

Fan vent ducting appears to be terminated in the attic; moisture can build up in the attic and damage the structure. We recommend a qualified contractor evaluate all the bathroom ducting in the house and repair as needed.

Electrical

NJ Standard of Practice

Service Equipment

Volts 120/240

Service Drop Underground

Service Entrance (SE) conductor Size Copper, #1, 150 amps

Main Panel Amperage 200 amps

Electric Service Amperage 150 amps

Main Electric Panel Location Garage

(E-3) Repair:

Contamination (paint splatter, drywall compound and other items) and excessive insulation on wires in panel; this is a fire hazard. Recommend a licensed electrician correct.

(E-4) Repair:

A piece of wood is filling the space between the dead front panel door and the wall; this is a fire hazard. Recommend a licensed electrician or qualified general contractor correct.

Sub Panels

None noted

Branch Wiring

Wire Material Copper

Wiring Method Non-metallic sheathed cable

(E-5) Repair:

Inquire with the seller about the extension cord used. What is this for? Extension cords should not be used for permanent electrical fixtures. Install proper wiring or remove extension cord as needed.

Receptacles and Fixtures

Inspection Method Random Testing

Electric Receptacles Three wire receptacles

Smoke and Carbon Monoxide Detection Systems

None noted

Grounding Electrode / Conductor

Present

Plumbing

NJ Standard of Practice

Water Service Supply

Pipe Material Copper

Well or Public Supply Public water

Pressure Reducing Valve Present

Main Water Shut-off Location Meter

(P-2) Repair:

The pressure reducing valve located in the garage across from the water heater is corroded and appears to be actively leaking at the time of inspection. We recommend further investigation and repair by a licensed plumber.

(P-3) Repair:

The floor below the pressure reducing valve is water soaked and structurally damaged, we recommend a qualified contractor, evaluate before closing, all the flooring and structure below it and repair as needed.

Distribution Pipe

Pipe Insulation Not visible

Supply Pipe Materials Copper

Functional Flow Average

(P-4) Repair:

The supply pipe insulation is incomplete in the crawl space. Be sure all supply lines in unheated spaces have been adequately insulated to protect from freezing conditions that could damage the pipes and to prevent heat loss. We recommend a qualified contractor evaluate and correct.

Waste Pipe and Discharge

Discharge Type Public sewer

Waste and Vent Pipe Materials Not visible

Water Heater

System Type Tank

Manufacturer GE

Size 40 gal

Age 18

Energy Source Gas

Temperature Pressure Relief Value Present - Not Tested

Serial Number GENG 0801H07665

Model Number PG40T9A

(P-5) Note:

Water heaters have an expected useful life of 6 to 12 years; this water heater is 18 years old.

(P-6) Repair:

The discharge tube for the water heater relief valve is installed too high off the ground. Discharge tubes should always terminate by pointing toward the ground to eliminate a scald hazard and should be no more than 6" off the ground. Ideally, the discharge tube terminates to an exterior or unfinished location or above a drain, though this is not always possible. The drain should also slope to drain to prevent water pooling inside the discharge tube and should be visible so it can be monitored. The end of the tube should not be threaded to prevent accidental capping of this important discharge. Have a licensed plumber evaluate and repair before the closing.

Exterior Hose Bibs

Operating

Washer

Tested

(P-8) Improve:

For improved reliability, update the old water supply connectors to the washing machine. These are old and should be regularly swapped out to prevent accidental leaks from bursting hoses. Consider improving the reliability of this water supply by installing a steel belted hose system.

(P-9) Improve:

A moisture alarm with water shut-off features is recommended under the washing machine to protect against accidental leaks in the supply hoses. Pans can be effective when there is a drain, but even these will not protect against a burst supply connector. A moisture alarm with automatic shut-off will.

Dryer

Tested

Power Source Gas and electric

Duct to Exterior Ducted

(P-10) Note:

It is recommended that the exhaust pipe and flex pipe be cleaned and changed shortly after you have closed on this home to guarantee that the dryer exhaust system is safe and working efficiently.

Heating

NJ Standard of Practice

Heating System

Energy Source Natural gas

Heating Method Hydronic boiler

Manufacturer Burnham

Capacity 80,000 btu's

Age 20+, unknown

Last Service Record None

Model Number P-204-WNV

Serial Number 17 217008

Condition Functional

(H1-2) Repair:

Annual servicing is recommended for safe and reliable heat. Records indicate that this boiler has not been serviced in the last year. The boiler was tested during inspection and was operational. Hire a licensed heating contractor to service and further evaluate the boiler.

(H1-3) Repair:

Corrosion observed at boiler vent and surrounding valves; this can leak or burst; we recommend a licensed HVAC contractor evaluate the boiler before closing and repair as required.

Thermostats

Present

Location First Floor

Heating Accessories

None Noted

Safety Switch/Disconnect Location On the wall, Near the unit

Condition Not Tested

Heating / Cooling Distribution Systems

Heat Source in Each Room Present

Distribution Method AC Ductwork, Hydronic Radiators

Air Handler Locations Attic

Additional Heat Sources

None noted

Cooling

NJ Standard of Practice

Cooling Systems

Present

Manufacturer U.S. Alumacoil Manufacturing Company, Goodman

Energy Source Electric

Age Air Handler 3 years, Compressor 4 years

Model ARUF37C14AA, GSX130361EC

Serial Number 1605402690, 1512077740

(C-3) Repair:

AC Condenser power switch is rusted and loosely attached to the siding; this is a fire hazard; we recommend a licensed electrician evaluate the service box before closing and repair/replace as required.

(C-4) Note:

The air condition system and condensate control system could not be tested during inspection. Outdoor temperatures must exceed 65 degrees or the air conditioning equipment can be damaged by testing. We recommended having this system serviced and inspected prior to the next cooling season.

Thermostats

Present

Location First Floor

Cooling Accessories

None Noted

Comments

Not Completed

Cooling Distribution Systems

Distribution Method Ductwork

Air Handler Locations Attic

Fuel Storage and Distribution

Oil Storage

None noted

Propane Storage

None noted

Gas Meter

None noted

Gas Pipe Materials Steel and flex pipe

(FSD-1) Due Diligence:

Gas meter was not observed; it's possible located behind the sellers stored materials; we recommend you ask the seller to point out the meter before closing; we recommend the meter be inspected before closing.

Structure

NJ Standard of Practice

Foundation

% of Foundation Not Visible 90%

Building Configuration Crawl space

Foundation Description Masonry block

Condition Not Completely Visible

Floor, Wall and Ceiling Framing

Wall Framing Not visible

Wall Insulation Not visible

Wall Sheathing Not visible

Floor Framing Partly visible

Sub-Floor Material Partly visible

Ceiling/Joist Framing Not visible

Girder/Beam Material Not Visible

Condition Not Completely Visible

Wood Destroying Insect Infestation

Not Inspected - Recommend Inspection by a Qualified Company

Comments

Finished Walls/Ceilings Prohibit Full View, Painted Walls Prohibit Full View

Basement

NJ Standard of Practice

Type

None

Floor, Wall and Ceiling - Finished Area Only

Wall Material Plaster

Doors and Windows

Primary Window Type Wood

Crawl Space

Crawl Space Access

Method of Inspection Viewed at access

Vapor Barrier

Vapor Barrier Material Plastic on earth

(CS-1) Repair:

The plastic vapor barrier in the crawl space is incomplete. Use 6 mil black plastic to cover all exposed earth. This helps to reduce humidity and eliminate conducive pest conditions in the crawl space.

Crawl Space Ventilation

Ventilation Method Exterior wall vents

Posts and Footings

Standard

Insulation

Insulation Type Fiberglass

Approximate R-Value R-30

Moisture Conditions

Some signs

(CS-2) Repair:

Moisture observed from crawl space; this may be under the water pressure reducing valve in garage utility area; we recommend a qualified contractor evaluate all the floor sheathing and structure in the crawl space before closing.

Receipt -- Residential Home Inspection

Report #: 190513A
Inspection Date: 2019-05-13

Property Inspected For 
Sample Client Report
374 Passaic Street Fort Lee, NJ 07024

Inspection with Digital Report
Radon Testing

PAID


Optimal Home Inspections LLC
C/O Marshal Datkowitz
2600 John F Kennedy Blvd
Jersey City, NJ 07306
(551) 261-1264

Signed Contracts